  rcm500/1000 series 500/1000 w dc-dc converters the rcm500 and rcm1000 series converters are reliable power supplies for railway and transportation systems. they are optimized for 72 or 110 v railway batteries. the output delivers 24 v with 500 or 1000 w. the converters are designed for chassis mounting and exhibit a closed housing with cooling openings. many options are available, such as an output oring fet for redundant operation, output voltage adjustment, interruption time of 10 ms, shutdown input, and a monitoring relay (change-over contact). features ? optimized for 72 v or 110 v railway batteries ? output voltage 24 v ? closed housing for chassis mounting ? extremely high efciency and high power density ? low inrush current ? 3 connectors: input, output, auxiliary (option) ? overtemperature, overvoltage, overcurrent, and short-circuit protection ? many options available ? compliant to en 50155, en 50121-3-2, arema ? rohs-compatible for all 6 substances ? fire and smoke: compliant to en 45545 and nfpa 130 ? 5 year warranty safety-approved to the latest edition of iec/en 60950-1 and ul/csa 60950-1 table of contents page page description ............................................................................ 1 model selection .................................................................... 2 functional description .......................................................... 3 electrical input data ............................................................. 4 electrical output data ........................................................... 6 description of options .......................................................... 9 electromagnetic compatibility (emc) ................................. 11 immunity to environmental conditions ............................... 13 mechanical data ................................................................. 14 safety and installation instructions ..................................... 15 accessories ........................................................................ 17 1 1 pending 1 belfuse.com/power-solutions
page 2 of 17 model selection table 1: standard models input voltage output power efciency 2 model options v i min 1 [v] v i cont [v] v i max 1 [v] v o nom [v] i o nom [a] p o nom [w] min typ [%] 4.2 50.4 (72) 0 110 24 21 500 72rcm500-24 d, m, , f, k 24 41 1000 72rcm1000-24 77 (72) 17.5 154 24 21 500 .4 110rcm500-24 24 41 1000 .4 110rcm1000-24 1 short time see table 2 for details. 2 (flhfdw t a = 25 c, v i nom, i o nom , v o nom rqorsrqhg part number description operating input voltage v i cont (continuousl): 50.4 C 90 vdc ........................................................... 72 77 C 137.5 vdc ........................................................ 110 series ............................................................................. rcm output poer: 500 ..................................................................... 500 1000 ................................................................... 1000 ominal output oltage: 24 v ........................................................................... -24 auxiliar functions and options: out o, output oltage adust, sutdon 1 .................. d interruption time ........................................................... m oring ft .................................................................... q fuse built-in ................................................................... f pluggable connectors ................................................. 1 opt. d reuires te auxiliar connector. note: the sequence of options must follow the order above. note: all models are rohs-compliant for all six substances. 110 rcm 500 -24 d m f k available combinations of options: 72/110rcmxxx-24 (k) 72/110rcmxxx-24d (k) 72/110rcmxxx-24df (k) 72/110rcmxxx-24dm (k) 72/110rcmxxx-24dmf (k) example: 110rcm500-24dm: dc-dc converter, input voltage range 77 to 17.5 v continuousl, output providing 24 v /21 a, monitoring rela, output vol tage adjust, shutdown input, active current sharing, interruption time 10 ms, integrated oring fet, rohs-compliant for all six sub stances. product marking tpe designation, applicable safet approval and recognition marks, ce mark, pin allocation, and product logo. input voltage range and input current, nominal output voltage and current, degree of protection, batch no., serial no., and dat a code lfolsurfwlrvlwhhuvlrprlfdwlrvwdwvddwhrisurfwlr tech.support@psbel.com belfuse.com/power-solutions bcd.00803 rev ac, 10-may-2018 rcm series 500 / 1000 w dc-dc converters ? 2018 bel power solutions & protection
page 3 of 17 functional description the input voltage is fed via an efcient input flter and a step-up converter (switching with 2 110 khz) to the high-efcient dc-dc converter operating at a switching frequency of ap prox i mately 90 khz. the built-in over voltage limiter protects against input voltage surges. the inrush current is limited by an electronic circuitry. a vdr resistor protects against external surges. if there is no external circuit breaker, the converter can be ordered with built-in fuse (opt. f). this fuse is not accessible. the circuitry to provide the interruption time (opt. m) is located after the input flter together with the reverse polarity protection formed by a fet. the rectifcation on the secondary side is provided by syn chronous rectifers, in order to keep the losses as low as possible. the output voltage control logic is located on the secondary side and controls the fets of the dc-dc converter via insulated drivers. an auxiliary converter supplies all circuits with a stable bias voltage. an output oring fet is available (opt. q) and allows for a redundant power supply system. opt. d encompasses an additional signal connector to allow for output voltage adjustment, active current sharing, primary shutdown, and an output voltage monitor activating a relay with change-over contact. the converter is mounted onto a base plate which acts as cooling plate. an additional heatsink for natural convection cooling is available as accessory. a thermal protection on the input and output side prevents from overheating. vi ? vi+ isolation vo? auxiliary connector (only with option d) vo+ auxiliary converter c y pe opt. q fuse (option f) opt. m input filter 1 reverse polarity protection (fet) , only fitted with opt. f or m 2 bipolar suppressor diode with opt. f or m output filter vdr jm201e secondary control logic t t r? r r r+ ntc + + c hu primary control logic sd0 sd input filter c y 1 ok0 ok2 ok1 insulated driver c i insulated driver 2 fig. 1 block diagram tech.support@psbel.com belfuse.com/power-solutions bcd.00803 rev ac, 10-may-2018 rcm series 500 / 1000 w dc-dc converters ? 2018 bel power solutions & protection
page 4 of 17 electrical input data general conditions: - t a = 25 c, unless specifed. table 2a: input data of rcm500 models input 72rcm500-24 110rcm500-24 unit characteristics conditions min ws max min ws max v i operating input voltage i o = 0 C i o max t a min C t a max 50.4 (72) 90 77 (110) 137.5 v v i 2s for 2 s without shutdown 43.2 100.8 66 154 v i nom nominal input voltage 72 110 v i abs input voltage limits 3 s without damage 0 108 0 165 i i typical input current v i nom, i o nom 7.3 4.8 a p i 0 no-load input power v i min C v i max, i o = 0 2.5 4 2.5 4 w p i sd idle input power v i min C v i max, v sd = 0 v 2 3 2 3 c i input capacitance 1 7 7 f r i input resistance 14 14 m i inr p peak inrush current v i = v i max, p o nom 20 20 a t inr d duration of inrush current 0.5 0.5 ms t on duration of inrush current 0 v i min, p o nom 300 500 300 500 start-up time after removal of shutdown v i min, p o nom v sd = 0 5 v 300 500 300 500 table 2b: input data of rcm1000 models input 72rcm1000-24 110rcm1000-24 unit characteristics conditions min ws max min ws max v i operating input voltage i o = 0 C i o max t a min C t a max 50.4 (72) 90 77 (110) 137.5 v v i 2s for 2 s without shutdown 43.2 100.8 66 154 v i nom nominal input voltage 72 110 v i abs input voltage limits 3 s without damage 0 108 0 165 i i typical input current v i nom, i o nom 15 9.5 a p i 0 no-load input power v i min C v i max, i o = 0 3 4 3 4 w p i sd idle input power v i min C v i max, v sd = 0 v 2.5 3 2.5 3 c i input capacitance 1 7 7 f r i input resistance 14 14 m i inr p peak inrush current v i = v i max, p o nom 40 40 a t inr d duration of inrush current 0.5 0.5 ms t on duration of inrush current 0 v i min, p o nom 300 500 300 500 start-up time after removal of shutdown v i min, p o nom v sd = 0 5 v 300 500 300 500 1 not smoothed by the inrush current limiter at start-up (for inrush current calculation) tech.support@psbel.com belfuse.com/power-solutions bcd.00803 rev ac, 10-may-2018 rcm series 500 / 1000 w dc-dc converters ? 2018 bel power solutions & protection
page 5 of 17 input transient and reverse polarity protection a dr resistor and a symmetrical input flter form an eective protection against input transients, which typically occur in many installations, but especially in battery-driven mobile applications. if the input voltage has the wrong polarity, the incorporated reverse diode will cause the external input circuit breaker or fuse to trip. with option m or f (incorporated fuse), an active reverse-polarity protection circuit prevents from any damage. input under- / overvoltage lockout if the input voltage is out of range, an internally generated signal dis ables the converter to avoid any damage. efciency see fg 60 70 80 90 0.4 0.8 p o / p o no m 0 jm216 100 [%] 0.6 0.2 11 0rcm500-24dmq v i = 137 v v i = 77 v 60 70 80 90 0.4 0.8 p o / p o nom 0 jm215 100 [%] 0.6 0.2 11 0rcm1000-24dmq v i = 110 v v i = 137 v v i = 77 v fig. 2a efciency versus v i and p o (110rcm500-24dmq) fig. 2b efciency versus v i and p o (110rcm1000-24dmq) tech.support@psbel.com belfuse.com/power-solutions bcd.00803 rev ac, 10-may-2018 rcm series 500 / 1000 w dc-dc converters ? 2018 bel power solutions & protection
page 6 of 17 electrical output data general conditions: - t a = 25 c, unless t c is specifed - r input not connected table 3: output data output 72/110rcm500-24 72/110rcm1000-24 unit characteristics conditions min ws max min ws max v o output voltage 1 v i nom , 0.5 i o nom 23.76 24 24.24 23.76 24 24.24 v v ow worst case output voltage v i min C v i max t c min C t c max , 0 - i o nom 23.28 24.72 23.28 24.72 v o droop output voltage droop - 10 - 5 mv/a v o l overvoltage shutdown 6 28 28 v v o p overvoltage protection 2 28.5 30 31.5 28.5 30 31.5 i o nom nominal output current t c min C t c max 21 42 a i o l output current limit 23 45 v o output noise 3 switching frequency v i nom , i o nom bw = 20 mhz 240 240 mv pp total incl. spikes 480 480 v od dynamic load regulation voltage deviation 5 v i nom , 0.1 ? 0.9 i o nom 1000 1000 t d 4 recovery time 5 5 ms vo temperature coefcient of v o (ntc) 0 - i o nom, t c min C t c max - 0.02 0 - 0.02 0 %/k 1 if the output voltage is increased above v o nom through r-input control, the output power should be reduced accordingly, so that p o max and t c max are not exceeded. 2 breakdown voltage of the incorporated suppressor diode at 1 ma . exceeding this value might damage the suppressor diode. 3 measured according to iec/en 61204 with a probe described in annex a 4 recovery time until v o returns to 1% of v o ; see fg. 3. 5 no overshoot at switch on. 6 output overvoltage shutdown by an electronic circuitry, with automatic recovery. output voltage regulation v od v od t d t d v o 1 % v o 1 % t t 10 s 10 s v o 0 0.5 1 i o /i o nom 05102c fig. 3 typical dynamic load regulation of output voltage tech.support@psbel.com belfuse.com/power-solutions bcd.00803 rev ac, 10-may-2018 rcm series 500 / 1000 w dc-dc converters ? 2018 bel power solutions & protection
page 7 of 17 output current limitation the output is continuously protected against open-circuit (no load) and short-circuit by an electronic current limitation with rectan - gular characteristic; see fg. 4. v o v o nom 0.98 0.5 0 0.5 1.0 i ol i o i o nom jm097 fig. 4 rectangular current limitation 6hhv3ddoohorqqhfrq5hgqgdqf the outputs of several rcm series converters may be con nected in series. note : if the sum of the output voltages is greater than 60 v, it cannot be considered being selv (safety extra low voltage) according to the safety standards. but the voltage may exceed the selv level. the outputs rcm series converters may be con nected in parallel. in order to ensures proper current sharing, the load lines should have equal length and section. the output voltage exhibits a slight droop characteristic, which facilitates current sharing. in addition, the output voltage tends to be lowered with increasing temperature. converters with option d exhibit an additional pin t to provide active current sharing by simply interconnecting all t- pins. for redundant systems, we recommend option q, which exhibits oring diodes built by fets, in order to keep the losses to a minimum. figure 5 shows a system with 3 parallel-connected converters forming a redundant system. the output voltage is increased by the resistor r ext2 (as an example). the ok signals, connected in series, allow for monitoring all 3 converters. vo? vo+ t vi? vi+ sd0 ok1 ok2 r+ r? ok0 110rcm1000-24dq sd r load vo? vo+ t vi? vi+ sd0 ok1 ok2 + jm237 r+ r? ok0 110rcm1000-24dq sd r vo? vo+ t vi? vi+ sd0 ok1 ok2 r+ r? r ext2 ok0 110rcm1000-24dq sd r ? input ok sd r ext2 r ext2 fig. 5 parallel connection of 3 converters tech.support@psbel.com belfuse.com/power-solutions bcd.00803 rev ac, 10-may-2018 rcm series 500 / 1000 w dc-dc converters ? 2018 bel power solutions & protection
page 8 of 17 thermal considerations and protection a temperature protection is incorporated in the primary and secondary control logic each. it generates an internal inhibit signal, which disables the converter in case of over tem per a ture. the converter automatically recovers, when the temper a ture drops below the limit; see fg. 6. the relationship be tween t a and t c depends heavily upon the conditions of operation and the integration into a system. caution: the installer must ensure that under all operating con ditions t c remains within the limits stated in table 7. 0 200 400 600 800 50 60 70 80 90 100 p o [w] t a [c] 1000 rcm1000 jm252 t c max convection cooling rcm500 40 with heatsink (dotted lines) fig. 6 7sfdorssrzhghdqhvvhpshdh hfdoprqqsrvrqihhfrqhfrqfrroq led indicator each converter exhibits a green led out ok, signaling that the output voltage is inside the specifed range. tech.support@psbel.com belfuse.com/power-solutions bcd.00803 rev ac, 10-may-2018 rcm series 500 / 1000 w dc-dc converters ? 2018 bel power solutions & protection
page 9 of 17 description of options option d: output monitor, output adjust, shutdown option d consists of several auxiliary functions (r, ok, sd, t) and en compasses an additional auxiliary connector. output voltage adjust (r) note: with open r-input, v o = v o nom . the converter allows for adjusting the output voltage in the range of 80 to 105% of v o nom . the adjust is accomplished by an external resistor r ext1 or r ext2 , connected to input r; see fg. 7. depending on the value of the required output voltage, the resistor shall be connected: either: between the pins r and rC to adjust the output voltage to a value below v o nom : v o r ext1 4 k : ? __________ C 15.8 k : v o nom C v o note: r ext1 = 0 : reduces v o to 80%. or: between the pins r and r+ to adjust the output voltage to a value greater than v o nom : ( v o C 2.5 v) r ext2 4 k : ? __________________ C 682 k : 2.5 v ? ( v o / v o nom C 1) note: r ext2 = 0 : increases v o to 105%. r? r+ vo? 4 k v ref = 2.5 v r ext1 r ext 2 jm191 vi? vi+ + control logic bias 628 k 15.8 k r fig. 7 output voltage control via r-input output voltage monitor (ok) the output voltage v o is monitored. when v o is in range, a relay with a changeover contact connected to the auxiliary connector is activated, and ok0 is connected with ok1. note: the trigger levels are typ. 5 % of v onom (with open r-input). data of relay contacts: 0.4 a /150 vdc. primary shutdown (sd) the output of the converter may be enabled or disabled by a logic signal (e.g. cmos) applied between the shutdown pin sd and sd0 (= viC). if the shutdown function is not re quired, pin sd can be left open-circuit. voltage on pin sd: converter operating: 12 v to v i max or open-circuit converter disabled: C 2 to +2 v the output response is shown in fg.8 note : in systems consisting of several converters, this feature may be used to control the activation sequence by logic signals or to enable the power source to start up, before full load is applied. tech.support@psbel.com belfuse.com/power-solutions bcd.00803 rev ac, 10-may-2018 rcm series 500 / 1000 w dc-dc converters ? 2018 bel power solutions & protection
page 10 of 17 current share function in parallel operation (t) just interconnect the t-pins of all converters to balance their output currents. only a single-wire connection is needed. 0 t 0 sd 1 0.1 1 v o /v o nom t on t f jm193a t off t r t hu t d on fig. 8 typical output response to the sd-signal. if option m is not ftted, t hu = 0 ms. 2srq425q)(7ir5hgqgdq6vhpv two parallel connected converters are separated with oring diodes (built by fets). if one converter fails, the remaining one still delivers the full power to the loads. if more power is needed, the system may be extended to more parallel converters (n+1 re - dundancy). current sharing must be ensured by load lines of equal section and length. in addition, a slight droop characteristic of the outputs and a negative temperature coefcient are helpful as well. to keep the losses as small as possible, the oring diode is replaced by a fet. note: in the case of a failing converter, the output voltage is maintained by the redundant converters. however, the failing item should be identifed and replaced. we recommend the out ok function (option d). option m: interruption time the interruption time t hu is specifed in the railway standard en 50155:2017 clause 5.1.1.4: class s2 is 10 ms. it is measured at v b nom (nominal battery voltage) for interruption and short-circuit of the input. after such an event, the system is ready for the next event after 10 s. fig. 6 shows the output voltage v o , if option m is ftted. option m encompasses a backrush pro tection formed by a fet device. for less critical applications, option m is not required (class s1). such units have a slightly better efciency. option f: incorporated fuse the railway standard en 50155 does not recommend fuses in converters. consequently, the installer should preview an external fuse or circuit breaker. however, when this is not possible, we ofer an in corporated fuse (option f) with active reverse polarity protection formed by a fet device. the fuse is not accessible and will not trip, unless the converter is really defect. the type of the incorporated fuses is specifed in table 4. such fuses are also recommended for external fuses. table 4: recommended external fuses (same as with option f) converter shflfdwlr ordering number 72rcm500-24 15 a fast acting littlefuse 0505015.mx52 lep 110rcm500-24 15 a fast acting littlefuse 0505015.mx52 lep 72rcm1000-24 110rcm1000-24 25 a fast acting littlefuse 0505025.mx52 lep option k: pluggable connectors this option allows the use of preassembled pluggabale con nectors; for details see accessories . note: female connectors must be ordered separately. tech.support@psbel.com belfuse.com/power-solutions bcd.00803 rev ac, 10-may-2018 rcm series 500 / 1000 w dc-dc converters ? 2018 bel power solutions & protection
page 11 of 17 electromagnetic compatibility (emc) electromagnetic immunity table : electromagnetic immunity (type tests) phenomenon standard level coupling mode 1 value applied waveform source imped. test procedure in oper. perf. crit. 2 electrostatic discharge (to case) iec/en 61000-4-2 4 3 contact discharge 6000 v p 1/50 ns 330 150 pf 10 pos. & 10 neg. discharges yes a air discharge 8000 v p electromagnetic feld iec/en 61000-4-3 x 4 antenna 20 v/m am 80% / 1 khz n/a 80 C 800 mhz yes a 5 antenna 20 v/m am 80% / 1 khz n/a 800 C 1000 mhz yes a 10 v/m 1400 C 2000 mhz 5 v/m 2000 C 2700 mhz 3 v/m 5100 C 6000 mhz electrical fast transients/burst iec/en 61000-4-4 3 6 capacitive, o/c 2000 v p bursts of 5/50 ns; 2.5/5 khz over 15 ms; burst period: 300 ms 50 ? 60 s positive 60 s negative transients per coupling mode yes a 3 i/c, +i/Ci direct surges iec/en 61000-4-5 3 7 i/c 2000 v p 1.2 / 50 s 42 ? 5 pos. & 5 neg. surges per coupling mode yes a +i/C i 1000 v p 0.5 f conducted disturbances iec/en 61000-4-6 3 8 i, o, signal wires 10 vac (140 dbv) am 80% / 1 khz 150 ? 0.15 C 80 mhz yes a power frequency magnetic feld iec/en 61000-4-8 3 9 300 a/m 60 s in all 3 axis yes a 1 i = input, o = output, c = case 2 a = normal operation, no deviation from specs.; b = normal operation, temporary loss of function or deviation from specs possible 3 exceeds en 50121-3-2:2016 table 5.3. 4 corresponds to en 50121-3-2:2016 table 5.1. 5 corresponds to en 50121-3-2:2016 table 5.2. 6 corresponds to en 50121-3-2:2016 table 3.2. 7 covers or exceeds en 50121-3-2:2016 table 3.3. 8 corresponds to en 50121-3-2:2016 table 3.1 (radio frequency common mode). 9 corresponds to en 50121-4:2016 table 2.3. tech.support@psbel.com belfuse.com/power-solutions bcd.00803 rev ac, 10-may-2018 rcm series 500 / 1000 w dc-dc converters ? 2018 bel power solutions & protection
page 12 of 17 electromagnetic emissions the conducted emissions (fg. 9) have been tested accord ing to en 55011, group 1, class a (similar to en 55032), much better values than requested by en 50121-3-2:2016, table 2.1. the limits in fg. 9 apply to quasipeak values, which are always lower then peak values. radiated emissions have been tested as per en 55011, group 1, class a, similar to en 61000-6-4+a1:2011, table 1. the test was executed with horizon tal and vertical polarization; the worse result is shown in fg. 10. 0 db v 20 40 60 80 110rcm500-24dmqf; vi = 110 v, vo = 24 v; io = 21 a class a, 25-may-2017 jm225 en 55011 a av en 55011 a qp 0.2 0.5 1 2 5 10 20 mhz 0 db v 20 40 60 80 110rcm500-24dmqf; vi = 110 v, vo = 24 v; io = 21 a class a, 25-may-2017 jm225 en 55011 a av en 55011 a qp 0.2 0.5 1 2 5 10 20 mhz 0 db v 20 40 60 80 110rcm1000-24dmqf; vi = 110 v, vo = 24 v; io = 42 a class a, 25-may-2017 jm227 en 55011 a av en 55011 a qp 0.2 0.5 1 2 5 10 20 mhz fig. 9a 50 7sfrqgfhggvdqfhvdhqs (v i =110 v, i i nom , uhvlvwlhordgtxdvlshdndqgdhudjh fig. 9b 50 7sfrqgfhggvdqfhvdhqs (v i =110 v, i i nom , uhvlvwlhordgtxdvlshdndqgdhudjh 30 50 100 200 500 1000 mhz db v/m 10 20 30 40 0 60 emc labatory, 110rcm500-24dmqf; vi = 110 vdc, vo = 24 v / 21 a ets-3143b testdistance 3 m, class a, 25-may-2017 jm226 50 qp limit en 55011, group 1, class a, 3 m 30 50 100 200 500 1000 mhz db v/m 10 20 30 40 0 60 emc labatory, 110rcm500-24dmqf; vi = 110 vdc, vo = 24 v / 42 a ets-3143b testdistance 3 m, class a, 25-may-2017 jm228 50 qp limit en 55011, group 1, class a, 3 m fig. 10a 50 7sdgdhggvdqfhvqpgvdqfh (v i = 110 v, i i nom , uhvlvwlhordgtxdvlshdn fig. 10b 50 7sdgdhggvdqfhvqp distance (v i = 110 v, i i nom , uhvlvwlhordgtxdvlshdn tech.support@psbel.com belfuse.com/power-solutions bcd.00803 rev ac, 10-may-2018 rcm series 500 / 1000 w dc-dc converters ? 2018 bel power solutions & protection
page 13 of 17 immunity to environmental conditions table : mechanical and climatic stress air pressure hpa test method standard test conditions status ad low temperature start-up test en 50155:2017, clause 13.4.4 iec/en 60068-2-1 temperature, duration: - 40 c, 2 h not operating performance test: +25 c be dry heat test, cycle a en 50155:2017, clause 13.4.5 iec/en 60068-2-2 temperature: 70 c operating perf. crit. a duration: 6 h db 2 cyclic damp heat test en 50155:2017, clause 13.4.7 iec/en 60068-2-30 temperature: 55 c and 25 c not operating cycles (respiration efect): 2 duration: 2x 24 h ka salt mist test sodium chloride (nacl) solution en 50155:2017, clause 12.2.10 iec/en 60068-2-11 class st3 temperature: 35 2 c converter not operating duration: 28 h functional random vibration test en 50155:2017 clause 13.4.11.4 en 61373:2010 clause 8, class b, body mounted 1 acceleration amplitude: 0.1 g n = 1.01 m/s 2 operating perf. crit. a frequency band: 5 C 150 hz test duration: 30 min (10 min in each axis) simulated long life testing en 50155:2017 clause 13.4.11.2 en 61373:2010 clause 9, class b, body mounted 1 acceleration amplitude: 0.58 g n = 5.72 m/s 2 not operating frequency band: 5 C 150 hz test duration: 15 h (5 h in each axis) shock test en 50155:2017 clause 13.4.11.3 en 61373:2010 clause 10, class b, body mounted 1 acceleration amplitude: 5.1 g n operating perf. crit. a bump duration: 30 ms number of bumps: 18 (3 in each direction) vibration sinusoidal arema part. 11.5.1 class c, d, e, i, j acceleration amplitude: 0.3 (5 C 20 hz) 1.5 g n = 14.7 m/s 2 operating perf. crit. a frequency: 10 C 200 hz test duration: 12 h (4 h in each axis) mechanical shock arema part. 11.5.1 class c, d, e, i, j acceleration amplitude: 10 g n = 98 m/s 2 operating perf. crit. a bump duration: 11 ms number of bumps: 18 (3 in each direction) 1 body mounted = chassis of a railway coach temperatures 7deoh7hpshudwuhvshflfdwlrvdoliruddlusuhvvuhrikdpedu model rcm500 rcm1000 unit en 50155:2017 class ot4 en 50155:2017 class ot2 characteristics conditions min max 10 min min max 10 min t a ambient temperature converter operating - 40 70 85 - 40 55 2 70 c t c case temperature 1 - 40 90 90 t s storage temperature not operational - 55 85 - 55 85 1 measured at the measurement point t c ; see mechanical data. 2 rcm1000 can be operated at higher temperature with reduced output power. reliability table : mtf and device hours ratings at specifed case temperature between failures model mtbf demonstrated hours 1 accord. to iec 62380 110rcm500-24dmqf 1 120 000 h 110rcm1000-24dmqf 1 110 000 h 1 statistical values, based upon an average of 4300 working hours per year and in general feld use over 5 years; upgrades and customer-induced errors are excluded. tech.support@psbel.com belfuse.com/power-solutions bcd.00803 rev ac, 10-may-2018 rcm series 500 / 1000 w dc-dc converters ? 2018 bel power solutions & protection
page 14 of 17 mechanical data dimensions in mm.  4 .5 (4x) vo+ vo? vi? vi+ pe measuring point of case temperature t c jm206d 10.95 53.65 99.65 7 92.75 70.5 209 197 147.05 123 141 9.0 6 40 71.5 66 heatsink fixation 2x m3 6 13.9 53.7 99.4 7 vo+ vo? vi? vi+ pe jm204e measuring point of case temperature t c 92.75 147.05 197 209 123 6 9.0 heatsink fixation 2x m3 6 70.5 71.5 66 vo+ vo? vi? vi+ pe 10.95 53.65 99.65 46 141 13.9 53.7 99.4 7 vo+ vo? vi? vi+ pe r c m 500/ 1000 s tandard r c m 500/ 1000 with option k fig. 12 case for rcm500 (rcm03), aluminum, ep powder-coated; 1160 g. fig. 13 case for rcm1000 (rcm04), aluminum, ep powder-coated; 1250 g. 6 17.7 pluggable connector jm246 european projection fig. 14 case detail for rcm500/1000 with option k tech.support@psbel.com belfuse.com/power-solutions bcd.00803 rev ac, 10-may-2018 rcm series 500 / 1000 w dc-dc converters ? 2018 bel power solutions & protection
page 15 of 17 safety and installation instruction connectors and pin allocation - input connector, 3 pins: wago 745-353: vi+, viC, pe; wire sections: rcm500 /1000: 0.2 C 6 mm 2 , 24 C 10 awg; with option k: weidmller 1048500000 - o utput connector, 2 pins: wago 745-652/006-000: vo+, vo; wire sections: rcm500/1000: 0.2 C 16 mm 2 , 24 C 06 awg with option k: weidmller 1048390000 xloldu frqqhfwru3krhql&rqwdfwslqdoorfdwlrq vhhj r r + r r ? t t n.c. n . c . o k 0 ok1 o k 0 ok2 n.c. n . c . s d 0 s d fig. 15 auxiliary connector pin allocation installation instruction these converters are components, intended exclusively for inclusion by an industrial assembly process or by a pro fessionally competent person. installation must strictly follow the national safety regulations in respect of the enclosure, mounting, creepage distances, clearances, markings and segregation requirements of the end-use application. &rqqhfwlrq wr wkh vvwhp vkdoo rqo eh hhfwhg zlwk fdeohv zlwk vxlwdeoh vhfwlrq sulpdu dqg vhfrqgdu frqqhfwru lq fdjh fodps technique). the auxiliary connector shall be connected via the suitable female connector; see accessories . other installation methods may not meet the safety requirements. check that pe is safely connected to protective earth. no fuse is incorporated in the converter (except for option f). an external circuit breaker or a fuse in the wiring to one or both input pins. r qrw rshq wkh frqhuwhuv ru wkh zduudqw zloo eh lqdolgdwhg 0dnh vxuh wkdw wkhuh lv vxflhqw dlurz ddlodeoh iru frqhfwlrq frrolqj dqg wkdw wkh whpshudwxuh ri wkh erwwrp sodwh lv zlwklq wkh vshflhg udqjh 7klv vkrxog eh hulhg e phdvxulqj wkh fdvh whpshudwxuh dw wkh vshflhg phdvxulqj srlqw zkhq wkh frqhuwhu lv rshudwhg lq wkh hqgxvh dssolfdwlrq t c max should not be exceeded. ensure that a failure of the converter does not result in a hazardous condition. standards and approvals the rcm series converters are approved according to the last edition of iec/en 60950-1 and ul/csa 60950-1. they have been evaluated for: ? class i equipment ? building in ? double or reinforced insulation based on 250 vac or 240 vdc between input and output, and between input and ok signals (relay contacts) ? pollution degree 2 environment the converters are subject to manufacturing surveillance in accordance with the above mentioned ul standards and with iso 9001:2008. cleaning liquids and protection degree the converters are not hermetically sealed. in order to avoid possible damage, any penetration of liquids shall be avoided. the converters correspond to protection degree ip 30. tech.support@psbel.com belfuse.com/power-solutions bcd.00803 rev ac, 10-may-2018 rcm series 500 / 1000 w dc-dc converters ? 2018 bel power solutions & protection
page 16 of 17 railway applications the rcm series converters have been designed observing the railway standards en 50155:2017, en 50121-3-2:2016, and arema. ooerdugvduhfrdwhgzlwkdsurwhfwlh odftxhu 7khfrqhuwhuvfrpsozlwkwkhuhvprnhvwdqgdug(1+/wr+/ insulation test the electric strength test is performed in the factory as routine test in accordance with en 50514 and iec/en 60950 and arema. ,w vkrxog qrw eh uhshdwhg lq wkh hog 7kh &rpsdq zloo qrw krqru zduudqw fodlpv uhvxowlqj iurp lqfruuhfwo hhfxwhg hohfwulf strength tests. table 9: isolation characteristics input to output to case ok contacts to unit output 1 case + output input case outputs electric strength test factory test 1 s 4.2 2.86 2 2.86 2.86 2.86 2.86 kvdc ac test voltage equivalent to factory test 3.0 2.0 2.0 2.0 2.0 2.0 kvac insulation resistance >300 3 >300 3 >300 >300 >300 >300 m ? creepage distances 5.0 3.5 3.5 3.5 3.5 3.5 mm 1 pretest of subassemblies in accordance with iec/en 60950 2 additional test with 1500 vdc during 10 s as per en 50155:2017. 3 tested at 500 vdc tech.support@psbel.com belfuse.com/power-solutions bcd.00803 rev ac, 10-may-2018 rcm series 500 / 1000 w dc-dc converters ? 2018 bel power solutions & protection
page 17 of 17 accessories female connector a suitable 16 pin female connector is available; see fg. 16. for converters rcm500/1000 with option k, use (see fg. 17): ? hzz00303-g (3 poles, weidmller 1060580000) ? hzz00302-g (2 poles, weidmller 1060550000). wire section: 0.5 C 10 mm 2 , 24 C 8 awg fig. 16 female connector 16 pins, hzz00146-g 3rhqrqdf fig. 17 )hpdohfrqqhfrvir50zrsrq. additional heatsink a suitable heat sink (hzz00149-g) for free air cooling is available, if cooling by wall or a chassis mounting is not possible; see fg. 18. visible surface a a a-a b 67.5 0.2 71.5 0.2 66 0.1 c 135 (209) 6 6 d c (2x) 0.2 90 ? 3.4 d (2x) m4 >6 8 1 b (4x) 6 6 r 6 ? 4.5 jm224a ? 6 fig. 18 ggrqdohdvqir50dqg rcm1000 (hzz00149-g) weight 530 g &rqwhqw+hdwvlqnvfuhzv (m3 x 6 mm) nuclear and medical applications - these products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. technical revisions - the appearance of products, including safety agency certifcations pictured on labels, may change depending on the date manufactured. specifcations are subject to change without notice. tech.support@psbel.com belfuse.com/power-solutions bcd.00803 rev ac, 10-may-2018 rcm series 500 / 1000 w dc-dc converters ? 2018 bel power solutions & protection


▲Up To Search▲   

 
Price & Availability of 110RCM1000-24DMQFK

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X